← Back to your report

HAVS assessment and testing

Written by the HAVi technical team · Checked by Joel Clarke, Technical Director · 24 November 2026

A HAVS assessment checks your hand-arm vibration risk against the Control of Vibration at Work Regulations 2005: which tools and tasks expose your people, for how long, and what you have to do about it. Testing measures how much your tools actually vibrate in your work, to BS EN ISO 5349-2, so the figures in your risk assessment are your own. You do not always need testing: HSE says to measure only when you cannot get suitable data from other sources.

Assessment and testing are different jobs

AssessmentTesting
What it answersIs your programme doing what the Regulations require?How much does this tool vibrate when your people use it?
What happensWe review your risk assessment, tool register, trigger times, controls, health surveillance and training records against the Regulations and HSE’s guidance.We measure each tool on site, in your conditions, with instruments meeting BS EN ISO 8041, mounted where vibration enters the hand.
What you getA written report: what is in place, the gaps, and the order to close them in.The vibration magnitude of each tool in m/s², its points an hour, and how long it can be used before the action and limit values.
When you need itWhen you set up a programme, after a significant change, or when you want an independent view before an inspection or audit.When you cannot find figures that represent your tools in use, or when the figures you have do not match what you see on site.

When you need your tools measured

The Regulations let you assess exposure using information on how much a tool is likely to vibrate in your conditions, such as manufacturers’ data, with measurement where necessary. HSE lists the usual sources: its own typical values for an initial assessment, equipment handbooks, figures from suppliers and online databases of in-use data.

HSE also warns that some manufacturers’ figures, measured in laboratory test conditions, may substantially underestimate vibration in the workplace. Measurement is worth doing when:

  • you cannot find a figure that represents your tool doing your work;
  • the figures you have do not match what operators report, or what you see;
  • a tool is close to a time limit, so the accuracy of its figure decides how long it can be used;
  • you are fitting trigger timers and want the points they report to rest on your own measured figures.

Before you book measurement, check theToolAdvisor for in-use figures on the same make and model.

How a tool is measured

HSE’s guidance says measurement should follow BS EN ISO 5349-2 and be carried out by a competent person, using instruments that meet BS EN ISO 8041. The sensor is fixed to the tool as close as possible to where vibration enters the hand. HSE says readings taken on the fingers, the back of the hand or the wrist are unlikely to be representative.

Results vary with the operator’s technique, the tool’s condition, the material and the method, so each tool is measured doing the work it does, with the people who use it.

What a HAVi assessment involves

  • Before the visit: we ask for your risk assessment, tool list and any exposure records, so the day goes on the gaps.
  • On site: we walk the work with a supervisor, measure the tools that matter most, and talk to operators about trigger times, symptoms and how the tools behave.
  • The report: each tool’s measured magnitude, points an hour and time to 100 and 400 points; the gaps against the Regulations, legal requirements first; and the order to close them in.
  • If you use HAVi monitoring: we load the measured figures into HAVi-Total Diagnostix, so the points your trigger timers report rest on your own tools.

What to have ready

Your current risk assessment, a list of the vibrating tools in use, who uses them and for roughly how long, and any health surveillance results you are allowed to share. None of it has to be complete: finding the gaps is the point of the visit.

Talk to us about an assessment

Face to face on your site, or online. We’ll start with where you are now.

Book a meeting

The Control of Vibration at Work Regulations 2005, regulation 5 (legislation.gov.uk/uksi/2005/1093). HSE, Vibration risk assessment (hse.gov.uk/vibration/hav/assessrisks.htm). HSE, Guidance on measurement and monitoring (hse.gov.uk/vibration/hav/measurement-monitoring.htm).